跳到主内容

1511

1511.2

RK 16/35/N BG

RK 16/35/N BG

Feed-through terminal, Screw connection, Mounting type: Mounting rail TS 35/7.5, Rated cross-section: 16 mm², Width: 12 mm, Colour: Beige

Download datasheet

Technical data

Rated current
76 A
Rated voltage
800 V
Rated cross-section
16 mm²
Connection principle
Screw connection
Colour
Beige
Width
12 mm
Length
54 mm
Mounting type
Mounting rail TS 35/7,5
CSA Usegroup C: rated current
85 A
CSA Usegroup C: rated voltage
600 V
CSA approval
C22.2 No 158
CSA approval granted
Yes
CSA file number
042110_0_000
CSA stripping length
15 mm
CSA wire cross-section AWG, max.
4
CSA wire cross-section AWG, min.
12
CSAus Usegroup C: rated current
85 A
CSAus Usegroup C: rated voltage
600 V
CSAus approval
UL 1059
CSAus approval granted
Yes
CSAus file number
042110_0_000
CSAus stripping length
15 mm
CSAus wire cross-section AWG, max.
4
CSAus wire cross-section AWG, min.
12
Connection position
Lateral
Connections
2
Contamination degree
3
DNV GL Certificate number
TAE000014T
DNV GL Location Classes
Temperature: B, Humidity: B, Vibration: A
DNV GL approval granted
1
DNV GL rated cross-section
16 mm²
DNV GL rated current
76 A
DNV GL rated voltage
800 V
DNV GL test standard
IEC 60947-7-1:2002
EAC approval
TR ZU 004/2011
EAC approval granted
Yes
EU-POP compliant
Yes
Flammability class UL 94
V-2
Gauge plug acc. to EN 60 947-1
B7
Height TS 35/7.5
47 mm
Insulating housing
Polyamide 6.6
KEMA KEUR approval
EN 60947-7-1:2009
KEMA KEUR approval granted
Yes
KEMA rated current
76 A
KEMA rated impulse voltage
8 kV
KEMA rated voltage
800 V
KEMA wire cross-section single-core (rigid), max.
25 mm²
KEMA wire cross-section stranded, max.
16 mm²
Maximum power dissipation for nominal condition
2.43 W
Number of cross-connection channels
1
Number of levels
1
Number of terminals per level
2
Overvoltage category
III
PROP 65 compliant
Yes
REACH Candidate Substance Note
No
REACH compliant
Yes
REACH reference date
2026-02-04
Rated impulse voltage
8 kV
RoHS compliant
Yes
Screw head
Slotted
Screw threading
M 5
Stripping length
15 mm
TSCA compliant
Yes
Tightening torque, max.
4 Nm
Tightening torque, min.
2 Nm
UL File Number
E95701
UL Recognized
1
UL Usegroup C: rated current
85 A
UL Usegroup C: rated voltage
600 V
UL approval
UL 1059
UL factory wiring
Yes
UL field wiring
Yes
UL torque
20 Lb In
UL wire cross-section single-core (rigid) AWG, max.
4
UL wire cross-section single-core (rigid) AWG, min.
10
UL wire cross-section stranded AWG, max.
4
UL wire cross-section stranded AWG, min.
10
UL wire material
Cu
Weight per piece (including packaging)
28.44 g
Weight per piece (not including packaging)
27 g
Wire cross-section AWG, max.
6
Wire cross-section AWG, min.
10
Wire cross-section single core (rigid)/stranded, max.
25 mm²
Wire cross-section single-core (rigid) / stranded, min.
2.5 mm²
Wire cross-section stranded with wire-end ferrule, min.
2.5 mm²
Wire cross-section stranded with wire-end ferrules, max.
16 mm²
Wire cross-section stranded, max.
16 mm²
Wire cross-section stranded, min.
2.5 mm²
Working temperature, max.
105 °C
Working temperature, min.
-40 °C
cUL Recognized
1
cUL Usegroup C: rated current
85 A
cUL Usegroup C: rated voltage
600 V
cUL approval
C22.2 No 158
cUL file number
E95701
cUL torque
20 Nm
cUL wire cross-section single-core (rigid) AWG, max.
4
cUL wire cross-section single-core (rigid) AWG, min.
10
cUL wire cross-section stranded AWG, max.
4
cUL wire cross-section stranded AWG, min.
10
cUL wire material
Cu

Commercial data

Country of origin
CZ
Customs number
85369010
GTIN (EAN)
4044211046118

Enquire about this article

Contact us

Send us the article numbers,
we take it from there

Selection, samples, lead time, manufacturer datasheets — we reply within one working day. Or open any article and enquire there.

  • Email [email protected]
  • Phone / WeChat 021-5433 7015
  • Address 4F Building 2, No.500 ShuHai Rd, Songjiang · P.R. China
  • Office hours Mon–Fri, 9:00–17:00
  • Operated by Shanghai ILERDA Electrical Equipment Co., Ltd.